Lab Sensor
ORP sensor
  • Shown as the figure:
    · It is the ORP combination sensor for lab and it is unnecessary to refill KCL solution.
    · Measurement rang: ±2000mV.
    · Temperature rang: 0~80℃.
    · The wetted parts : plastic(blue, black, white or other colour).
    · The external dimension of the sensor is φ12x120mm.

    Selection of model

    · For common occasion:

       ASRS2503-1 (black) 
       ASRS2503-2 (blue) 

       ASRS2503-3 (transparent) 

       ASRS2503-4(light blue)

       ASRS2503-5(yellow) 

    · Double junction:

       ASRSDJ2503-1 (black) 
       ASRSDJ2503-2 (blue) 

       ASRSDJ2503-3 (transparent)

       ASRSDJ2503-4 (light blue)

       ASRSDJ2503-5(yellow)

  • Shown as the figure:
    · It is the refilling ORP combination sensor for lab.
    · Measurement rang: ±2000mV.
    · Temperature rang: 0~80℃.
    · The outer tube material : plastic(blue, black, white or other colour).
    · The external dimension of the sensor is φ12x120mm .

    Selection of model:

    · For common occasion:

       ASRS2503C-1 (black) 
       ASRS2503C-2 (blue) 

       ASRS2503C-3 (transparent)

       ASRS2503C-4 (light blue)

       ASRS2503C-5 (yellow)  

    · Double juction:

       ASRSDJ2503C-1 (black) 
       ASRSDJ2503C-2 (blue) 

       ASRSDJ2503C-3 (transparent)

       ASRSDJ2503C-4 (light blue)

       ASRSDJ2503C-5 (yellow) 

  • Shown as the figure:
    · It is the ORP combination sensor for lab.
    · Measurement rang: ±2000mV.
    · Temperature rang: 0~80℃.
    · The outer tube material : glass.
    · The external dimension of the sensor is φ12x120mm. 

    Selection of model:

    · For common occasion:

       ASR2503G     it is unnecessary to refilling KCL solution

       ASR2503GC   it is necessary to refilling KCL solution

    · Double juction:

       ASRDJ2503G     it is unnecessary to refilling KCL solution 

       ASRDJ2503GC   it is necessary to refilling KCL solution

  • Shown as the figure:
    · It is the single measuring ORP sensor for lab.
    · Measurement rang: ±2000mV.
    · Temperature rang: 0~80℃.
    · The outer tube material : glass or plastic.
    · The external dimension of the sensor is φ12x120mm.

    Selection of model:

    · ASR4211 single ORP sensor (glass outer tube)

    · ASRS4211 single ORP sensor(plastic outer tube)

  • Shown as the figure:
    · It is the ORP reference sensor for lab.
    · Temperature rang: 0~80℃.
    · The outer tube material : glass or plastic.
    · The external dimension of the sensor is φ12x120mm.

    Selection of model:

    · ASR3101 single reference ORP sensor (Glass outer tube) 

    · ASR3101C refillable single reference ORP sensor (Glass outer tube)   

    · ASRS3101 single reference ORP sensor (Plastic outer tube)

    · ASRS3101C  refillable single reference ORP sensor(Plastic outer tube)